• VIVA TECH
      • VIVA TECH

      • Millimeter-Wave Amplifiers, Active Frequency Multipliers, VCO Frequency Sources, PLO Based Frequency Sources, Waveguide Mixers, Detectors, Isolators, Variable/ Fixed Attenuators, Couplers, Filters, Horn Antennas, Downconverter Modules, Frequency Extension TR_R Module Sets, Cryogenic Primary Noise Standard
    • Impedance Matching Tuners and Pulsed IV RF<br> Measurements, Device characterization and Modelling
    • Frequency Extension products
      • Frequency Extension products

      • Frequency Extension products- expand existing Vector Network Analyzer (VNA), Singal generator, Spectrum Analyzer capabilities up to 325GHz, LNA amplifiers, Radar Front End Module up to W Band, CobaltFx mm-wave VNA Test and Measurement, CobaltFX Calibration Kit and Cables, Block down Converters, Amplifiers, Calibration Kit (FEK), Frequency Converters, Frequency Sources, Harmonic Mixers (WHMB), Mixer and Detectors, Multipliers, Noise Sources, Planar Detectors…
    • EMERGENCY LOCATOR TRANSMITTER (ELT)
      • EMERGENCY LOCATOR TRANSMITTER (ELT)

      • The system comes with a transmitter, portable/survival antenna, mounting bracket, external whip antenna with a 6-foot coax cable, and a battery pack. Since it is installed near the pilot a remote control monitor is not required. If the ELT is activated a built-in monitor emits a loud beeping tone and the LED flashes. The portable/survival antenna allows the ELT to…
    • DESIGN AND DEVELOPMENT OF LOAD BANK
      • DESIGN AND DEVELOPMENT OF LOAD BANK

      • AC RESISTIVE LOAD BANK 115V AC 3 PH /150A / 50HZ 1. Load input Voltage 115 V AC 3 ph 50Hz CURRENT : 150A 2. Specification. CAPACITY 30 KW 3. Load selections TP MCB'S 4. No.of steps : Total : 7 steps ,5A* 1 NO,10A* 2 Nos 25A* 3 NOs, 50A* 1NO. AC RESISTIVE LOAD BANK 115V AC 3 PH…
    • DESIGN AND DEVELOPMENT AC TO DC CONVERTOR
      • DESIGN AND DEVELOPMENT AC TO DC CONVERTOR

      • Input Voltage:- 95 V AC to 198.75 V AC, Phase to Neutral. Nominal: 162.5V AC Frequency:- 500 Hz Input power compliance: MIL-STD 704-D Output Power:- 350 Watts Output Voltage:- 28 Vdc + 0.5 V / -1.5 V Efficiency :- > 85 % Over Voltage Protection:- MIL-STD 704-D Under Voltage Protection:- MIL-STD 704-D BIT:- Health OK Overload capacity:- 150% for 5…
    • Data Acquisition System (DAQ)
      • Data Acquisition System (DAQ)

      • HIGH-END DAQ SYSTEMS Most flexible and distributable single slices with USB and EtherCAT® interface. Synchronized, highly reliable data logger and powerful data processing computer. High-speed data acquisition system (15 MS/sec) with the new Hybrid ADC technology capable of high-bandwidth transient recording and very highdynamic, alias-free data acquisition. Integrated solution with 4 SIRIUS slices and powerful SBOX computer or USB hub…
    • Flight Data Recorder (FDR)
      • Flight Data Recorder (FDR)

      • Flight Data Recorder (FDR) - a device used to record specific aircraft performance parameters. The purpose of an FDR is to collect and record data from a variety of aircraft sensors onto a medium designed to survive an accident. An FDR has historically been one of two types of "flight recorder" carried on aircraft, the other being a cockpit voice recorder…
    • Frangible Switch
      • Frangible Switch

      •   PIN  Signal Name  Destination  Type  Specification  Definition  Direction A  Operate  AIRCRAFT Discrete  Single wire Normally Low, Active  High.  16-32Vdc, <3.5Amps  OUT B +28Vdc Aircraft   Power Supply AIRCRAFT  DC  Single wire  16-32Vdc, <3.5Amps IN C  0V Aircraft Return  AIRCRAFT  DC  Single wire  0V Aircraft Return  Common
    • Test Bench
      • Test Bench

      • A test bench or testing workbench is an environment used to verify the correctness or soundness of a design or model. The term has its roots in the testing of electronic devices, where an engineer would sit at a lab bench with tools for measurement and manipulation, such as oscilloscopes, multimeters, soldering irons, wire cutters, and so on, and manually verify the correctness of the device under…
    • Hydrostatic Switch
      • Hydrostatic Switch

      • Specifications - • Setpoint range from 5 to 105 psi • Deadband range from 3.5 psi or 15%, whichever is greater, to 45% of the setpoint • Proof pressure up to 300 psi • Pressure capsule all stainless steel, heliarc welded and leak proof to 1 X 10-9 SCC/SEC • SPDT snap action switch element • Electrical rating 1 amp…

End of content

No more pages to load